| Audio |
| |
Typical of 6 Room Outputs: |
| |
Controls |
Volume, Balance, Bass, Treble, Loudness, Mute, Mono, Input Compensation |
| |
Volume Gain Range |
-80dB to +20dB, 1 dB steps |
| |
Mute |
-100dB (electronic), -120dB (relay) |
| |
Input Compensation |
±10dB |
| |
Bass Gain Range |
±12dB @ 100Hz, 2 dB steps |
| |
Treble Gain Range |
±12dB @ 10kHz, 2 dB steps |
| |
Frequency Response |
20Hz to 20kHz ±0.75dB |
| |
S/N Ratio |
100dB, 20Hz to 20kHz A-weighted |
| |
THD+N |
0.05%, 20Hz to 20kHz |
| |
Stereo Separation |
>75dB |
| Connectors |
| |
SOURCES 1 – 10 |
(40) RCA female providing (10) unbalanced stereo line-level audio inputs, and (10) parallel loop-thrus; Maximum Input: 3.2 Vrms (flat); Input Impedance: 47k ohms; Connect to audio loop-thru from AADS or AES, or other source devices, with loop-thru to additional AAE units |
| |
ROOMS 1 – 6 |
(12) 2-pin 7.62mm detachable terminal blocks, power amplifier outputs; Wire Size: 12 AWG maximum; Output Power (per Channel): 45 Watts at 8 ohms, 60 Watts at 4 ohms |
| |
NET 1 – 6 |
(6) 4-pin 3.5mm detachable terminal blocks; Cresnet distribution ports, provide data and power for keypads and other Cresnet devices |
| |
LOOP THRU |
(2) 4-pin 3.5mm detachable terminal blocks; Cresnet loop-thru ports; Y, Z, and G paralleled with NET ports 1 through 6; Connect to AADS, AES, or other 2-Series control system, and additional AAE units |
| |
FUSE |
Main fuse, T8AH; (1/4” x 1-1/4”, 250V, 8A, time-lag, high-rupture rated) |
| |
120V~50-60Hz |
(1) IEC Male; mates with removable power cord (included) |
| |
G |
6-32 screw, chassis ground lug |
| Controls and LED Indicators |
| |
ROOM |
(6) Pushbuttons with green LEDs and backlit labeling strip, select room(s) to adjust |
| |
SETUP (rear) |
(1) Miniature pushbutton and red LED for touch-settable ID (TSID) |
| Power Requirements |
| |
Main Power Consumption |
7 Amps @ 120 Volts AC, 50-60Hz |
| |
Available Cresnet Power |
50 Watts (2.08 Amps @ 24 Volts DC) |
| Environmental |
| |
Temperature |
41° to 104°F (5° to 40°C) |
| |
Humidity |
10% to 90% RH (non-condensing) |
| |
Heat Dissipation |
700 BTU/hr @ 8 ohms, 800 BTU/hr @ 4 ohms; all channels loaded to 1/8 full power |
| Enclosure |
| |
Black metal with molded ABS/PC front panel; Freestanding, side ventilation should not be restricted |
| Dimensions |
| |
Height |
5.64 in (14.33 cm) |
| |
Width |
17.16 in (43.59 cm) |
| |
Depth |
18.08 in (45.92 cm) |
| Weight |
| |
36.6 lbs (16.2 kg) |
| INTERNATIONAL VERSION (230 VAC) |
| |
AAEI |
| |
All the features and specifications of the AAE except: |
| |
Connectors (partial) |
| |
FUSE |
Main fuse; T4AH; (5mm x 20mm, 250V, 4A, time-lag, high-rupture rated) |
| |
230V~3.5A |
(1) IEC Male; mates with removable power cord (included) |
| |
Power Requirements |
| |
Main Power Consumption |
3.5 Amps @ 230 Volts AC, 50Hz |
| |
Available Cresnet Power |
50 Watts (2.08 Amps @ 24 Volts DC) |
|
* Room outputs are expandable by cascading the inputs of multiple AAE units using standard RCA interconnect cables. Crestron recommends cascading no more than four (4) AAE units. Adagio systems may utilize up to three (3) AAE units in addition to the main unit. The actual number of possible units in a system is virtually unlimited, although additional equipment may be necessary to maintain signal integrity. Contact Crestron for assistance.
|