DIN-8SW8-I

8-Kanal-Relaismodul + 8 Eingänge

8-Kanal Relaismodul. Pro Kanal 16 A Glühlampe (ohmsche Last), 5 A Leuchtstofflampen (induktive Last). Cresnet Anschluss, frontseitige Handbedienung und Anzeige der Cresnet ID, Override Eingang. 8 digitale optisch entkoppelte Eingänge für 24 Volt DC, zum Anschluss von Kontaktgebern wie Taster, Schalter, Alarmkontakte, usw. Stand-alone Funktionalität ohne Busverbindung auf die Relais-Ausgänge. Z.B. Eingang 1 schaltet Relais 1 ein / aus. Format 9 TE.

The DIN-8SW8-I is an 8-channel lighting control module designed to support switching of non-dimmable lighting and fans. In addition, the DIN-8SW8-I features eight isolated digital inputs, allowing standard momentary switches to trigger events with or without a control system. A single model supports both 120 and 220-240 Volt applications. Each channel handles incandescent loads up to 10 Amps, fluorescent loads up to 5 Amps, and also 1/2 HP motors.[1]

Override Input
An override input is provided to allow an external contact closure to momentarily override the control system program and set each channel output to its override preset state. States can be set and saved locally from the front panel, or remotely via software.

Isolated Local Inputs
The DIN-8SW8-I provides 8 isolated local inputs, allowing momentary push button keypads to be used. By default, a momentary voltage applied on each input will cause the associated relay to toggle on/off. In addition, the attached Crestron control system can override this behavior to create 8 general-purpose inputs. In this mode, push button keypads can be programmed to provide customized functionality.

DIN Rail Installation
The DIN-8SW8-I is designed to snap onto a standard DIN rail for installation in a wall mount enclosure. Wiring connections are made using screw terminals positioned along the top and bottom, clearly accessible from the front for easy installation and servicing. All setup controls and indicators are positioned on the center front panel. When installed in an enclosure utilizing 45 mm cutouts, the DIN-8SW8-I's front panel stays accessible while the connections are concealed.

Cresnet®
The DIN-8SW8-I communicates with a DIN-AP2 2-Series Automation Processor, or other Crestron 2-Series control system, via the Cresnet control network. A pair of Cresnet ports is provided on the DIN-8SW8-I allowing for easy daisy-chaining of several DIN Rail Series automation control modules.

Key Features

 

  • 8 channels of power switching
  • 8 voltage-driven isolated digital inputs
  • Supports 120 to 240 Volt 50/60 Hz
  • Override input
  • Cresnet communications
  • Setup via front panel or software
  • Programmable functionality via DIN-AP2
  • 9M wide DIN rail mounting

Notes:

  1. May not be compatible with some high inrush current loads.

Load Ratings
  Switch Channels 8
  Maximum Per Channel 10 Amps incandescent, 5 Amps fluorescent, 0.5 HP @ 120 to 240 Volts AC, 50/60 Hz;
5 Amps @ 30 Volts DC;
16 Amps Resistive
  Module Total 80 Amps incandescent, 40 Amps fluorescent @ 120 to 240 Volts AC, 50/60 Hz
  Load Types[1] Incandescent, Magnetic Low-voltage, Electronic Low-Voltage, Neon/Cold Cathode, Fluorescent, Motors
Connections
  1 – 8 (8) sets of (2) captive screw terminals;
Isolated Class 1 SPST relay switch circuits 1 – 8;
Relay Rating: 10 Amps incandescent, 5 Amps fluorescent, 16 Amps resistive, 0.5 HP @ 240 Volts AC (per channel);
Maximum Wire Size: 12 AWG (2.5 mm²)
  INPUTS 1-8 (9) 3.5 mm detachable terminal blocks (inputs 1-8, common);
Rated for 12-24 Volts AC/DC; Input Impedance: 6.8k Ohms
  NET (2) 4-pin 3.5mm detachable terminal blocks, paralleled;
Cresnet slave port
  OVERRIDE (2) 2-pin 3.5mm detachable terminal blocks, paralleled;
Sensing input for external low-voltage contact closure;
Activates override mode when a closure is present;
Minimum Closure Rating: 10mA (per module) at 24 Volts
Controls & Indicators
  1 – 8 (8) Red LEDs and (8) miniature pushbuttons for status indication and local control of each channel
  NET ID (2) 7-Segment green LED digits and (2) miniature pushbuttons for setting Cresnet ID
  SETUP (1) Red LED and (1) recessed miniature pushbutton for enabling setup mode and touch-settable ID
  OVR (1) Red LED and (1) miniature pushbutton for enabling override mode and saving override presets
  PWR (1) Green LED, illuminates when DC power is applied to the NET port
  NET (1) Yellow LED, indicates communication with the control processor
  RESET (1) Recessed miniature pushbutton, resets internal processor
Enclosure
  Light gray polycarbonate housing with polycarbonate label overlay, UL94 V-0 rated, 35mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45mm front panel cutout, occupies 9 DIN module spaces (162mm)
Power Requirements
  Cresnet Power Usage 5.4 Watts (0.23 Amps @ 24 Volts DC)
Environmental
  Temperature 32° to 104°F (0° to 40°C)
  Humidity 10% to 90% RH (non-condensing)
  Heat Dissipation 18 BTU/hr
Dimensions
  Height 3.71 in (9.42 cm)
  Width 6.26 in (15.90 cm)
  Depth 2.35 in (5.95 cm)
Weight
  13.1 oz (369 g)

Publications

Spec Sheet

Spec Sheet (PDF)

Installation and Operations Guide

Installation And Operations Guide (PDF - 3.8 M)
Doc. No. 6930A
Rev. Date: 2/1/2010

CADs, Drawings and Revit Files

Zoomable Drawing

Zoomable Drawing

Cad Files

Cad Files (ZIP - 309 K)
Rev. Date: 10/17/2012

Available Models

Model Description      

DIN-8SW8-I

DIN Rail High-Voltage Switch with Digital Inputs

 

 

 

Invitation to Tender

DIN-8SW8-I (TXT - 1.53 KB)
Letzte Änderung 11.11.2012