Temperatur-Controller

Temperatur-Controller mit Prozessor und LCD Display, arbeitet autark und auch als Cresnet Busgerät zur Integration in das gesamte System, dadurch auch komplette Visualisierung und Bedienung über Touchpanel, ein- und mehrstufige Heizungs- und Klimaregelung, ein Temperatursensor ist eingebaut, bis zu 4 weitere Sensoren (CHV-RSS, CHV-RTHS) sind anschließbar.
CHV-TSTAT-A: mandelfarben
CHV-TSTAT-B: schwarz
CHV-TSTAT-W: weiß

The CHV-TSTAT is a versatile heating and cooling thermostat for one and two stage control of forced air, radiant, and heat pump HVAC systems. Relative humidity capability can be added through an external remote humidity sensor (sold separately). Although functional as a standalone thermostat, the CHV-TSTAT delivers greatly enhanced functionality as part of a complete Crestron Home® automation system. Available in white, black, or almond, the stylish wall mount design is a complement to any décor.

The large backlit LCD display, navigable using four simple pushbuttons, provides easy access to indoor and outdoor temperature and humidity readings, setpoint adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity setpoints with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.

Multiple Crestron thermostats may be networked via Cresnet to a PAC2, PAC2M, or other 2-Series control system, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.

Its connection to the control system also enables full control and scheduling of the CHV-TSTAT from touchpanels and computers throughout the home, and supports extensive flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT will remain operable to control the HVAC system.

Optional remote temperature and humidity sensors can be connected to the CHV-TSTAT for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low-temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity and two temperature sensors.

Awards

2008 Archi-Tech Readers

HVAC - CHV-TSTAT

Lighting - iLux™ CLS-C6M

The Archi-Tech Readers' Choice Awards recognize the most innovative products in today's commercial buildings market. Online readers, including architects, system designers, programmers and installers, vote annually for their favorite technology products in the areas of audio/video, building controls, glass and glazing, HVAC, lighting, security and sustainable technology. This year, Crestron Electronics earned honors in two separate categories. Crestron won in the HVAC category for the Crestron CHV-TSTAT heating and cooling thermostat and in the Lighting Category for the Crestron iLux CLS-C6M integrated lighting and shade control system.

 

Measurement Range
  Indoor Temperature 0° to 110°F (-18° to 43°C)
  Outdoor Temperature -40º to 170ºF (-40º to 77ºC)*
  Humidity 0% to 100% RH*
Temperature Tolerance
  Over Full Range ±1ºF (±0.5ºC)
  At Room Temperatures ±1ºF (+0.1/-0.4ºC)
Setpoint Range
  Auto Setpoint 38° to 99°F (3° to 37°C)
  Heat only Setpoint 38° to 89°F (3° to 32°C)
  Cool only Setpoint 59° to 99°F (15° to 37°C)
  Humidity Setpoint 5% to 70% RH*
Relay Rating
  1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
Power Requirements
  24V 2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
  Cresnet Power Usage  
Buttons
  MODE Accesses user controls - system mode, fan mode, humidifier*, Crestron system, and global update
  VIEW Accesses humidity reading*, outdoor temperature reading*, system messages, and remote functions
  UP Selects user modes and increments selection in setup modes
  DOWN Selects user modes and decrements selection in setup modes
Display
  Type Transflective LCD, backlit
  Size 2.75 in (6.99 cm)
  Resolution 128 x 64
  Viewing Angle ±50° horizontal (@0° vertical), ±50° vertical (@0° horizontal)
  Displays current indoor temperature and relative humidity*, outdoor temperature and relative humidity*, setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.
Connectors
  HVAC (2) 9-position terminal blocks comprising the following:

Power Connections (Required):
24 (C): 24V AC common terminal supplies remote 24V AC power to thermostat;
24 (R): 24V AC reference terminal – Can be connected to RH or RC by P4 jumper setting, or tied directly to power source

HVAC Control Connections (System Dependent):
HUM: Energized to RHU during humidity call;
RHU: Reference for humidifier;
RH: Reference Heat – Used for calls to heating system;
RC: Reference Cool – Used for calls to cooling system;
G: Fan – Energized to RC during call for fan;
Y/Y1: Compressor (stage one) – Energized to RC when compressor (or first stage) is run;
Y2: Compressor (stage two) – Energized to RC on two-stage systems on call for second stage;
O: Changeover control – Energized to RC during cooling modes;
B: Energized to RC during non-cooling modes;
W/W1: Heat (single stage)/heat (stage one) – Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
W2: Heat (stage two) – Energized to RH during a call for second stage heat in heat/cool systems

Remote Sensing Connections (Optional):
RSR: Remote Sensor Returns – Common sensor terminal;
RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR

  NETWORK (1) 4-position terminal block;
Cresnet slave port, connects to Cresnet control network
Enclosure
  Injection-molded plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
Dimensions
  Height 3.75 in (9.50 cm)
  Width 5.00 in (12.70 cm)
  Depth 1.04 in (2.63 cm)
Weight
  5.80 oz (165 g)

* Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately.

Crestron Green Light®: Sophisticated iLux Integration
Models Included: C2N-MNETGW, C2N-SDC, C2N-SDC-DC, C2N-SSC-2, CAEN, CHV-RSS, CHV-RTHS, CHV-TSTAT, CLS-C6M, CLW-DIM4RF, CLW-DIMS, CLW-DIMS1RF, CNX-B6, PAC2

Sophisticated iLux integration & automation configuration

Application Diagram (PDF - 8.15 M)
Rev. Date: 4/15/2009

Application Diagram

Crestron Mobile Pro® Typical Integration
Models Included: AMS-AIP, APAD, CEN-NVS100, CEN-WAP-ABG-1G, CHV-TSTAT, CRESTRON-MOBILE-PRO, TPMC-8X

Shows typical integration between Crestron Mobile Pro installed on an iPhone® and a Crestron system.

Application Diagram (PDF - 2.87 M)
Rev. Date: 7/12/2010

Application Diagram

Lighting, HVAC and A/V Application System
Models Included: CHV-TSTAT, PAC2, TPS-3000L

Sample lighting, HVAC and A/V system diagram featuring CLW-1DIM, CHV-STAT, TPS-3000L, and PAC2 controller.

Application Diagram (CAD/ZIP - 3.8 M)
Rev. Date: 2/6/2007

Application Diagram

Publications

Spec Sheet

Spec Sheet (PDF)

Manual

Manual (PDF - 3.03 M)
Doc. No. 8163C
Rev. Date: 6/22/2011

Manual

Manual (PDF - 3.78 M)
Doc. No. 8163D
Rev. Date: 6/18/2010
Note: For firmware 2.061.0018 and later.

Manual

Manual (PDF - 1.9 M)
Doc. No. 8163A
Rev. Date: 4/1/2004
Note: For firmware 1.1.x - 1.9.x

Manual

Manual (PDF - 1.9 M)
Doc. No. 8163B
Rev. Date: 3/1/2004
Note: For firmware up to 1.1

Quick-Start Guide

Quick-Start Guide (PDF - 1.8 M)
Doc. No. 6145A
Rev. Date: 8/1/2004

CADs, Drawings and Revit Files

Zoomable Drawing

Zoomable Drawing

Cad Files

Cad Files (ZIP - 303 K)
Rev. Date: 11/3/2004

Available Models

Model Description      

CHV-TSTATA

Heating and Cooling Thermostat, Almond Faceplate

 

 

 

CHV-TSTATB

Heating and Cooling Thermostat, Black Faceplate

 

 

 

CHV-TSTATW

Heating and Cooling Thermostat, White Faceplate

 

 

 

 

Available Accessories

Model Description      

CHV-RSS

Remote Slab Sensor and Outdoor Temperature Sensor

 

 

 

CHV-RTHS

Remote Temperature and Humidity Sensor

 

 

 

CHV-RTS

Remote Temperature Sensor

 

 

 

CRESNET-HP-NP-TL-SP1000

Cresnet® "High-Power" Control Cable, non-plenum, teal, 1000 ft spool

 

 

 

CRESNET-HP-NP-TL-SP500

Cresnet® "High-Power" Control Cable, non-plenum, teal, 500 ft spool

 

 

 

CRESNET-NP-BK-B500

Cresnet® Control Cable, non-plenum, black, 500 ft box

 

 

 

CRESNET-NP-OR-B500

Cresnet® Control Cable, non-plenum, orange, 500 ft box

 

 

 

CRESNET-NP-TL-B250

Cresnet® Control Cable, non-plenum, teal, 250 ft box

 

 

 

CRESNET-NP-TL-B500

Cresnet® Control Cable, non-plenum, teal, 500 ft box

 

 

 

CRESNET-NP-TL-SP1000

Cresnet® Control Cable, non-plenum, teal, 1000 ft spool

 

 

 

CRESNET-NP-TL-SP500

Cresnet® Control Cable, non-plenum, teal, 500 ft spool

 

 

 

CRESNET-NP-YL-B500

Cresnet® Control Cable, non-plenum, yellow, 500 ft box

 

 

 

CRESNET-P-BK-SP500

Cresnet® Control Cable, plenum, black, 500 ft spool

 

 

 

CRESNET-P-OR-SP500

Cresnet® Control Cable, plenum, orange, 500 ft spool

 

 

 

CRESNET-P-TL-SP1000

Cresnet® Control Cable, plenum, teal, 1000 ft spool

 

 

 

CRESNET-P-TL-SP500

Cresnet® Control Cable, plenum, teal, 500 ft spool

 

 

 

CRESNET-P-YL-SP500

Cresnet® Control Cable, plenum, yellow, 500 ft spool

 

 

 

Invitation to Tender

CHV-TSTAT-A (TXT - 477 B)
Letzte Änderung 11.11.2012

Invitation to Tender

CHV-TSTAT-B (TXT - 473 B)
Letzte Änderung 11.11.2012

Invitation to Tender

CHV-TSTAT-W (TXT - 471 B)
Letzte Änderung 11.11.2012